Use and precautions of palm centrifuge
release time:2023-02-08  |  Browse:1482

The palm centrifuge is mainly used for the separation of trace substances. Although it is small, its function is no worse than that of those guys! Take Yetuo HL-6KS for example, its size is only 175 * 135 * 120, but its maximum speed can reach 6000rpm.




The palm centrifuge can also be equipped with a variety of rotors and test tube sets to meet the needs of different experiments. At the highest speed, the centrifugal force of the palm centrifuge is quickly and evenly applied to the cap and wall of the microtube, especially suitable for processing PCR tubes and microfiltration.




Although the size of the palm centrifuge is small, the same precautions should be taken when using it.




Precautions for use of the instrument




1. The palm centrifuge should be placed in a horizontal position during use, the voltage of the external power supply should match the instrument, and a good grounding wire is required. Do not stack sundries around the instrument, and leave at least 10 cm of space for the instrument to dissipate heat.




2. Before starting the machine, check whether the rotating head of the palm centrifuge is firmly installed and whether there is any foreign matter falling into the cavity. Check whether the anchor bolt, drum, triangle belt and brake device are intact and can work normally.




3. The sample should be pre-balanced. When using the centrifuge cylinder, the centrifuge cylinder and the sample should be balanced at the same time. It is not only necessary to ensure the equal weight balance of the sample, but also consider the balance of density and volume. Because the moment generated by centrifugation is not only related to the type of sample, but also related to the selection radius of sample. If the centrifuge is started under unbalanced load, it may damage the equipment and even the operator.




4. When centrifuging volatile or corrosive liquids, centrifuge tubes with covers should be used to avoid liquid leakage and damage to the instrument or danger.




5. Avoid using non-standard test tubes to insert the centrifuge rotor.




6. Do not run the equipment when the top cover of the centrifuge is opened. After centrifugation, wait until the instrument stops rotating completely before opening the top cover. If the centrifuge is abnormal during operation, turn off the power immediately and report to the technician for maintenance.




7. The use time of the handheld centrifuge is generally 1 to 2 minutes. The laboratory personnel should take care of the whole process and should not leave to avoid accidents.




8. The palm centrifuge should be cleaned in time after use, and the action should be light when wiping the cavity to prevent damage to the temperature sensor.




9. The centrifuge should be placed at dry room temperature to avoid direct sunlight and severe temperature changes, and be waterproof and moisture-proof.


Previous:Applicable scope and precautions of low-temperature tank     Next:Precautions during use of vortex mixer
Follow us
Mobile station
  • Mobile:19961895916
  • Tel:19961895916
  • WeChat Account:上海叶拓科技
  • Email:yetuo@sh-yetuo.com
  • Address:C2-301, green window, No. 4, Lvdu Avenue
Copyright© 2024 Shanghai Yetuo Technology Co., Ltd  ICP备案号:沪ICP备20000740号-3