Product parameters:
Instrument model: YT-BOD50A (without printing function)
Measurement item: BOD (Biochemical Oxygen Demand)
Measurement range: 0-4000mg/L
Resolution: 0.01mg/L
Sampling points: ≤ 60 per cycle
Measurement principle: mercury free pressure difference method
Measurement accuracy: ± 8%
Data Storage: Massive Data Storage
Mixing: Program control, magnetic stirring
Measurement cycle: 1-30 days, recording frequency: 5min-3h/time
Measurement quantity: 6 independent groups for testing
Cultivation bottle volume: 580ml
Cultivation temperature: 20 ± 1 ℃
Power configuration: AC220V ± 10%/50-60HZ
Product size: 275x185x305mm
Yetuo YT-BOD50A BOD Biochemical Oxygen Demand Analyzer
Model: YT-BOD50A (without printing function)
Product Overview:
The BOD biochemical oxygen demand analyzer is based on the national standard "H1505-2009" 5-day cultivation method, simulating the biological hydrolysis process of organic matter in nature, and using a simple, safe, and reliable mercury free pressure difference sensing method to measure BOD in water; Fully intelligent design, leading R&D technology and design manufacturing, no need for laboratory personnel to be on duty during the experimental process; Suitable for biochemical oxygen demand measurement in the fields of polluting enterprises, environmental monitoring, sewage treatment plants, third-party testing institutions, scientific research, universities, etc.
Product Features of Yetuo YT-BOD50A BOD Biochemical Oxygen Demand Analyzer
Large size liquid product display screen, intuitive and clear, easy to select projects;
Can simultaneously measure six samples, six independent testing terminals, and add new measurement groups at any time during the testing process;
Directly read the B0D concentration value without calculation;
Mercury free pressure difference design, high accuracy, no conversion required, and ensuring the safety and health of experimental personnel;
There is no pipeline design in the experimental stage to avoid drawbacks such as pipeline aging and air leakage;
The measurement range can be selected, and no dilution is required when the water sample concentration is below 4000g/L;
The measuring instrument automatically records measurement data, with a selection of 60 sampling points per testing cycle for more accurate detection data;
The cultivation period can be adjusted and selected according to needs;
Automatically complete the measurement process without the need for dedicated personnel to be on duty;
The testing terminal comes with a large capacity battery, which can last for more than 2 years in standby mode and is not easily affected by short-term power outages in the external environment during the testing process;