Model :YT-BOD6A
Measurement item: BOD (Biochemical oxygen demand)
Measurement range: 0-4000mg/L
Resolution: 0.01mg/L
Sampling points: ≤ 60/cycle
Measurement principle: mercury free pressure difference method;
Measurement accuracy: ± 8%
Data storage: Massive data storage
Mixing: program control, magnetic stirring
Result recording frequency: 6min-3h/time
Measurement cycle: 1 day to 30 days
Measurement quantity: Independent 6 groups for testing
Volume of culture bottle: 580ml
Culture temperature: 20 ± 1 ℃
Power configuration: AC 220V ± 10%/50-60HZ
Product size: 275 * 185 * 305mm
- Product Details
- Product manual
Yetuo YT-BOD6A Intelligent BOD Analyzer
model: YT-BOD6A
Product Overview:
The HM series BOD biochemical oxygen demand analyzer is based on the national standard "HJ505-2009" 5-day cultivation method, simulating the biodegradation process of organic matter in nature, and using a simple, safe, and reliable mercury free pressure difference sensing method to measure BOD in water; Fully intelligent design, leading R&D technology and design manufacturing, no need for laboratory personnel to be on duty during the experimental process; Suitable for biochemical oxygen demand measurement in the fields of polluting enterprises, environmental monitoring, sewage treatment plants, third-party testing institutions, scientific research, universities, etc.
Product features of Yetuo YT-BOD6A intelligent BOD analyzer
Large size LCD display screen, intuitive and clear, easy to select projects
● Can measure six samples simultaneously
Six independent testing terminals can be added to a new measurement group at any time during the testing process
Directly read the BOD concentration value without the need for calculation
Mercury free pressure difference design, high accuracy, no conversion required, and ensuring the safety and health of experimental personnel
There is no pipeline design in the experimental stage to avoid drawbacks such as pipeline aging and air leakage
The measurement range can be selected, and no dilution is required when the water sample concentration is below 4000g/L
The measuring instrument automatically records measurement data, with 60 sampling points available in one testing cycle for more accurate detection data
The cultivation period can be adjusted and selected according to needs
Automatically complete the measurement process without the need for dedicated personnel to be on duty
The testing terminal comes with a large capacity battery, which can last for more than 2 years in standby mode and is not easily affected by short-term power outages in the external environment during the testing process